Products > Ancillary Machines > Thermoregulators
ATEM thermoregulators are designed to keep at constant temperature during production process moulds, parts of industrial machines, calendering rolls and, generally, all the components which cannot correctly perform their own function if their temperature uncontrollably changes. The tanks with thermoregulation fluid of thermoregulators are thermally insulated. The thermoregulators are constructed in such a way to allow an easy access to the inside components for the maintenance operations. Three series of thermoregulators are available and each series includes different capacity of the thermoregulation fluid tank and different heating powers.
ATEM production range includes:


Water thermoregulators TNA 10:
Overall dimensions: mm 270 (front side) x 700 x h.590
Tank capacity: lt 10
Heating power: kW 3 (version with direct cooling exchange) - kW 6 (version with indirect cooling exchange)
Pump power: kW 0,33 / HP 0,45
Pump flow rate: lt/h 380 – 2000
Pump head: bar 2,1 - 0,4
Chilling of thermoregulation water: direct by water (basic version) or indirect by heat exchanger.
Water thermoregulators TNA 10/2:
Overall dimensions: mm 540 (front side) x 700 x h.610.
The other technical data of each one of the two units of TNA 10/2 are equal to the TNA 10 above reported data.
Water thermoregulators TNA 50:
Overall dimensions: mm 450 (front side) x 880 x h.1020
Tank capacity: lt 50
Heating power: kW 9 (version with direct cooling exchange) - kW 18 (version with indirect cooling exchange)
Pump power: kW 1,1 / HP 1,5
Pump flow rate: lt/h 1200 – 6000
Pump head: bar 3,75 – 2,85
Chilling of thermoregulation water: direct by water (basic version) or indirect by heat exchanger.
Thermoregulator TNA 50/2:
Overall dimensions: mm 900 (front side) x 880 x h. 1020.
The other technical data of each one of the two units of TNA 50/2 are equal to the TNA 50 above reported data.
Water thermoregulators TNA 25:
Overall dimensions: mm 270 (front side) x 820 x h.750
Tank capacity: lt 25
Heating power: kW 6 (version with direct cooling exchange) - kW 9 (version with indirect cooling exchange)
Pump power: kW 0,33 / HP 0,45
Pump flow rate: lt/h 380 – 2000
Pump head: bar 2,1 - 0,4
Chilling of thermoregulation water: direct by water (basic version) or indirect by heat exchanger.
Water thermoregulators TNA 25/2:
Overall dimensions: mm 540 (front side) x 820 x h.770.
The other technical data of each one of the two units of TNA 25/2 are equal to the TNA 25 above reported data.